Mostra l’estatus de tots els controladors
[root@~]# hpacucli ctrl all show status
Smart Array E200i in Slot 0 (Embedded)
Controller Status: OK
Cache Status: Not Configured
Smart Array P600 in Slot 3
Controller Status: OK
Cache Status: OK
Battery/Capacitor Status: OK
Mostra l’estat de un slot en concret[root@~]# hpacucli ctrl slot=3 pd all show status
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, 300 GB): OK
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, 0 MB): Failed
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, 750 GB): OK
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, 750 GB): OK
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, 750 GB): OK
Mostra l’estat de tots els controladors[root@~]# hpacucli controller all show config
Smart Array E200i in Slot 0 (Embedded) (sn: QT78MU1027 )
Smart Array P600 in Slot 3 (sn: P92B30Y9SV6085)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (279.4 GB, RAID 1, Interim Recovery Mode)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 0 MB, Failed)
array B (SATA, Unused Space: 0 MB)
logicaldrive 2 (1.4 TB, RAID 5, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SATA, 750 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SATA, 750 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SATA, 750 GB, OK)
0 Comments.